SOLAR ENERGY SUPPLY · AFRICA Explore our brochure ↓

RESOURCES / SIZING GUIDE

Choose with the
whole day in mind.

A practical sequence for turning an appliance list and site plan into a system inquiry.

PLAN / COMPARE / CONFIRM

From load list to shortlist.

Build a daily energy picture

List each appliance, its rated input power and the hours it operates. Energy in kWh equals appliance power in kW multiplied by operating hours. Add the loads that will actually run together. Include standby consumption and ask an installer to account for system losses, seasonal conditions and reserve capacity.

Separate energy from power

Daily energy describes how much electricity you use over time. Maximum output describes the loads the system can serve at once. A battery capacity alone cannot establish whether a pump or refrigerator will start. Confirm continuous output, starting demand and the limits of each inverter.

Define the backup window

Identify essential circuits and their expected operating hours during an interruption. Usable battery energy depends on discharge limits, conversion losses and operating conditions. Do not treat the listed storage capacity as a promise of runtime. For longer interruptions, review recharge opportunities and any generator interface.

Check the space

The listed installation area is PV coverage, not a complete site layout. Leave room for maintenance, equipment, ventilation and local setbacks. Roofs, balconies, carports and fences need their own structural and electrical assessment. Check shading throughout the intended operating season.

Use the table as a shortlist

The figures below reproduce the supplied product table. Approximate daily generation is a comparison figure rather than a forecast for every African location. The ECP8K storage conflict is displayed explicitly. Send your location and load schedule for a final selection.

ModelPV kWpStorage kWhApprox. kWh/dayMax. kWArea m²
SSP-BP500-T1-G0.45Not listed1.80.451.99
SSP-BP1000-T1-2S0.4521.811.99
SSP-BP800-T2-G0.9Not listed3.60.83.98
SSP-BP1600-T4-5S1.857.21.67.96
SSP-PEG5K-A1-8S2.68812510.8
SSP-PEG8K-A2-16S5.361621.5821.61
SSP-ECP8K-C1-16S4.028 (summary); 16 (configuration)16816.21
SSP-XCP15K-C2-32S10.053240.21540.5
SSP-XCP30K-C4-64S20.16480.43081
SSP-PF5K-S10-8S2.68810.72512.85

Home Systems warranty

BC modules: 15-year product (workmanship) warranty and 30-year power warranty. Inverter and energy storage: 5-year warranty. Anti-backflow (export limiter) device: 3-year warranty.

SolarNova mounting components are a separate range: 10-year warranty / 25-year design life.