PRODUCT RANGE

Build around your application.

PV mounting and AIKO module supply alongside our established hybrid systems and diesel generator offering.

01 / SOLARNOVA MOUNTING

Rails, clamps and roof connections.

SN-R40 aluminum rail

SN-R40 aluminum rail

AL6005-T5 · 1.2 mm nominal wall · approx. 0.8 kg/m. Reference span approx. 1.0–1.6 m; verify by load calculation.

Ask about this product ↗

Mounting: 10-year warranty / 25-year design life. Typical lead time: 15–20 days after order and drawing confirmation. Spans and fixings require project-specific structural verification.

Homes, shops & telecom

HP5000

5 kW hybrid system · 5.12 kWh battery · 2 × 580 W PV

Enquire about HP5000 ↗

Original range specifications retained for configuration review. Final equipment, performance, protection ratings and compatibility must be confirmed in the order-specific technical schedule. Battery and hybrid equipment warranty terms are confirmed separately.

Technical Specifications

Power Output

Rated Power 5kW
Peak Power 7kW (10 sec)
Max PV Input 7kW
Output Voltage 220V/230V Single Phase
Frequency 50Hz / 60Hz (selectable)

Battery System

Capacity 5.12kWh
Expandable Up to 20.48kWh (4 units)
Type LiFePO4 (CATL)
Cycles 3000+ @ 80% DOD
Max Charge 100A

Efficiency

Inverter ≥95%
Battery Round-Trip ≥95%

Physical

Battery Size 530×180×620mm
Inverter Size 450×300×150mm
Total Weight ~80kg
IP Rating IP54 (Battery)
Operating Temp -10°C to +55°C

System Components

Component Specification Qty
PV Modules 580W PV module (original kit specification; module selection confirmed per order) 2 pcs
Battery 5.12kWh LiFePO4 (CATL) 1 pc
Hybrid Inverter 5kW Off-Grid, 48V Input 1 pc
Mounting System Aluminum Rail + Clamps 1 set
PV Cables 4mm² MC4 Pre-assembled 20m
AC Distribution Box 63A MCB + SPD 1 pc

Clinics, hospitality & farms

HS10000

10 kW hybrid system · 10.24 kWh battery · 4 × 580 W PV

Enquire about HS10000 ↗

Original range specifications retained for configuration review. Final equipment, performance, protection ratings and compatibility must be confirmed in the order-specific technical schedule. Battery and hybrid equipment warranty terms are confirmed separately.

Technical Specifications

Power Output

Rated Power 10kW
Peak Power 15kW (10 sec)
Max PV Input 13kW
Output Voltage 220V/230V Single Phase
DG Input Rating 15kW max

Battery System

Capacity 10.24kWh (4×2.56kWh)
Expandable Up to 40.96kWh
Type LiFePO4 (CATL)
Cycles 4000+ @ 80% DOD
Max Charge 140A

Efficiency

Inverter ≥96%
Battery Round-Trip ≥95%

Physical

Battery Stack Size 600×400×800mm
Inverter Size 500×350×200mm
Total Weight ~180kg
IP Rating IP54 (Battery)
Operating Temp -10°C to +55°C

System Components

Component Specification Qty
PV Modules 580W PV module (original kit specification; module selection confirmed per order) 4 pcs
Battery 10.24kWh LiFePO4 Stack (CATL) 1 stack
Hybrid Inverter 10kW HV Hybrid, Auto DG Start 1 pc
DG Auto-Start Module Included 1 pc
PV Combiner Box 4-string Input 1 pc
Mounting System Aluminum Rail + Clamps 1 set

Industry, mining & remote sites

HS30000

30 kW hybrid system · 43 kWh battery · 16 × 580 W PV

Enquire about HS30000 ↗

Original range specifications retained for configuration review. Final equipment, performance, protection ratings and compatibility must be confirmed in the order-specific technical schedule. Battery and hybrid equipment warranty terms are confirmed separately.

Technical Specifications

Power Output

Rated Power 30kW
Expandable Up to 120kW (4 units parallel)
Max PV Input 45kW
Output Voltage 380V/400V Three-Phase
Power Factor 0.8 lag to 0.8 lead

Battery System

Capacity 43kWh HV LiFePO4
Expandable Up to 172kWh
Battery Voltage 384V HV
Type LiFePO4 (CATL/EVE)
Cycles 6000+ @ 70% DOD

System Efficiency

Total AC-AC ≥98%
Inverter ≥97%
Battery Round-Trip ≥95%

Environmental

Operating Temp -10°C to +60°C
Humidity Up to 95% non-condensing
IP Rating IP54 internal, IP65 enclosures
Altitude Up to 4000m (with derating)

HYBRID CONTROL

Coordinate solar, battery and generator.

Solar-first

Use available PV to serve loads and charge the battery within configured limits.

Battery support

Use stored energy for load changes and planned backup needs.

Generator operation

Coordinate generator loading with PV and battery controls; verify reverse-power protection.

Standby & maintenance

Plan generator auto-start thresholds and maintenance windows around required autonomy.

DIESEL GENERATORS

Diesel power remains available.

Standalone diesel generators and generator supply for solar–diesel hybrid systems remain part of our range. Tell us the required prime or standby rating, voltage, frequency and operating environment.

The original site did not list standalone generator model numbers or verified generator datasheets. Generator selection, enclosure, fuel system, auto-start interface and inclusion in a hybrid package are confirmed per project.

Discuss diesel generators ↗

YOUR NEXT PROJECT

Let’s specify the right system.

Share your load profile, site location and installation drawings. We will review the supply scope with you.